Logo

ASTM E2015-04(2014)

Historical Reaffirmation

Standard Guide for Preparation of Plastics and Polymeric Specimens for Microstructural Examination

$83.00

$83.00

$149.40


Sub Total (1 Item(s))

$ 0.00

Estimated Shipping

$ 0.00

Total (Pre-Tax)

$ 0.00


...

1.1 This guide covers recommended procedures and guidelines for the preparation of plastic and polymeric specimens for microstructural examination by light and electron microscopy.

1.2 This guide is applicable to most semi-rigid and rigid plastics, including engineering plastics. This guide is also applicable to some non-rigid plastics.

1.3 The procedures and guidelines presented in this guide are those which generally produce satisfactory specimens. This guide does not describe the variations in techniques required to solve individual problems.

1.4 Many detailed descriptions of grinding and polishing of plastics and polymers are available (1-7).2

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


4.1 One of the fundamental objectives of microstructural examination of manufactured materials, especially plastics and polymers, is to gain a more complete understanding of the relationships between the manufacturing processes, the microstructure and texture of the material, and the product's performance (that is, physical, optical, or mechanical properties, or combination thereof). Under nearly all conditions, the proper selection and preparation of the specimen are of major importance.

4.2 Because of the wide range of available equipment; physical, chemical, and mechanical properties of materials; and the personal element, specimen preparation is an art based upon scientific principles. However, like metallographic specimen preparation, certain methods, practices, and procedures can be used to routinely produce acceptable quality plastic and polymeric specimens for microstructural examination. Acceptable quality means:

4.2.1 The observed microstructure is free of thermal, mechanical, and chemical alterations, artifacts, damage, or defects resulting from the specimen preparation process.

4.2.2 A surface finish appropriate for the microscopical techniques to be used.

4.2.3 The microstructure is reproducibly displayed for a given specimen.

4.3 The mounting, sectioning, grinding, and polishing procedures in this guide may introduce thermal, mechanical, and chemical stresses on the material being prepared for microstructural examination. Thus, knowledge of the material's physical, mechanical, and chemical properties is of importance in selecting the most appropriate technique(s) to reveal its true microstructure and to minimize the total number of steps needed to produce high quality polished specimens.

4.4 The general guidelines presented below will need to be modified for each type of plastic or polymer to be prepared. Table X1.1 presents general procedures for preparing plastics and polymers. Tables X1.2-X1.5 present procedures for preparing four polymers with very different mechanical properties.

SDO ASTM: ASTM International
Document Number E2015
Publication Date Oct. 1, 2014
Language en - English
Page Count 10
Revision Level 04(2014)
Supercedes
Committee E04.01
Publish Date Document Id Type View
Nov. 1, 2004 E2015-04 Revision
May 10, 1999 E2015-99 Revision
Sept. 1, 2021 E2015-04R21 Reaffirmation
Oct. 1, 2014 E2015-04R14 Reaffirmation
May 1, 2009 E2015-04R09 Reaffirmation