ASTM D6318-03

Historical Revision

Standard Practice for Calibrating a Fathometer Using a Bar Check Method (Withdrawn 2023)

$73.00

$73.00

$131.40


Sub Total (1 Item(s))

$ 0.00

Estimated Shipping

$ 0.00

Total (Pre-Tax)

$ 0.00


...

1.1 This practice provides the user with procedures used in manually calibrating the fathometer or electronic depth sounder. This narrative describes calibration terminology, describes acceptable environmental conditions for calibration, and describes the calibration procedures.

1.2 The references cited contain useful information in the construction and the correct operation of the calibration equipment.

1.3 Any references cited in this narrative to specific products or brand names are made for information only, and is intended to be descriptive, but not restrictive, of products that will perform satisfactorily.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


The accuracy of depth measurements made by a fathometer or echo sounder requires a number of corrections because of the variability of sound or acoustic velocity in water with changes in temperature, salinity, and depth of water. In addition instability of the equipment can also result in significant errors. For additional information see Practice D 5073.

Calibration of echo sounding instruments is absolutely critical in assuring the adequacy of depth measurements. When an echo sounder has been accurately calibrated, any observed (recorded) depth can be related to the true depth of water. Since the intended purpose of echo sounding is to measure the true depth, an independent true reference must be used.

A bar-check is the most wide-spread, easiest to construct, and most economical mechanical method to determine corrections for instrument and velocity errors.

This procedure explains the calibration of a fathometer or electronic depth sounder using a bar-check.

Bar-checking techniques and equipment are general in nature and may need to be modified for use in specific field conditions.

SDO ASTM: ASTM International
Document Number D6318
Publication Date Aug. 10, 2003
Language en - English
Page Count 3
Revision Level 03
Supercedes
Committee D19.07
Publish Date Document Id Type View
April 1, 2024 D6318-24 Revision
Jan. 1, 2014 D6318-03R14 Revision
Aug. 10, 2003 D6318-03 Revision
Sept. 10, 1998 D6318-98 Revision
Oct. 1, 2008 D6318-03R08 Reaffirmation