1.1 This practice covers procedures for surveying concrete bridge decks by sounding to determine delaminations in the concrete. It is not intended that the procedures described herein are to be used on bridge decks that have been overlaid with bituminous mixtures. The procedures may be used on bridge decks that have been overlaid with portland cement concrete mixtures; however, areas indicated to be delaminated may have a lack of bond between the overlay and the underlying bridge deck (Note 1).
1.2 The following three procedures are covered in this practice:
1.2.1 Procedure A, Electro-Mechanical Sounding Device—This procedure uses an electric powered tapping device, sonic receiver, and recorder mounted on a cart. The cart is pushed across the bridge deck and delaminations are recorded on the recorder.
1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of whoever uses this standard to consult and establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
| SDO | ASTM: ASTM International |
| Document Number | D4580 |
| Publication Date | Dec. 15, 2012 |
| Language | en - English |
| Page Count | 4 |
| Revision Level | 12 |
| Supercedes | |
| Committee | D04.32 |