1.1 This test method covers the evaluation of the performance of distillate fuels from the standpoint of clean, efficient burning. It is intended primarily for use with home heating equipment burning No. 1 or No. 2 fuel oils. It can be used either in the laboratory or in the field to compare fuels using a given heating unit or to compare the performance of heating units using a given fuel.

Note 1: This test method applies only to pressure atomizing and rotary-type burners.

1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.

1.2.1 Arbitrary and relative units are also used.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


5.1 This test method relates efficiency of operation of domestic heating equipment to clean burning. Reducing combustion air in a burner gives more efficient operation. The extent to which combustion air can be reduced is limited by the onset of unacceptable smoke production. By delineating the relation between smoke density and air supply, this test method (together with net stack temperature data) defines the maximum efficiency for a given installation at any acceptable smoke level.

5.2 For certain types of equipment, such as the rotary wall-flame burner, too much excess air will cause smoke as well as too little. For these cases, the point of minimum excess air at the acceptable smoke level indicates the optimum efficiency.

5.3 The operating temperatures of the equipment will affect these test results. The relation of excess air to smoke density is thus susceptible to some change at different points in an operating cycle. In practice, an adequate compromise is possible by operating the burner for 15 min before any readings are recorded and then obtaining the test data within a succeeding 25 min period.

5.4 Under laboratory conditions, CO2 readings are reproducible to ±0.3 % and smoke readings are reproducible to ±1/2 smoke spot number.

SDO ASTM: ASTM International
Document Number D2157
Publication Date Dec. 1, 2024
Language en - English
Page Count 3
Revision Level 24
Supercedes
Committee D02.E0
Publish Date Document Id Type View
Dec. 1, 2024 D2157-24 Revision
April 1, 2018 D2157-18 Revision
May 1, 2013 D2157-94R13 Reaffirmation
Dec. 1, 2008 D2157-94R08 Reaffirmation
Nov. 1, 2003 D2157-94R03 Reaffirmation
April 10, 1999 D2157-94R99 Reaffirmation